The Marlen S-2000 Natural Smoke Scrubber System provides an economical and reliable way to clean or scrub smokehouse gases to remove particulate matter created by a natural smoke generator. The simple, four (4) duct design creates four (4) separate washing chambers through which exhaust gases must travel. Fresh and re-circulated water is sprayed into the on-coming emission gas which removes particles and odors. An automatic level control maintains the correct water level in the reservoir. Maintenance of the removable spray headers is made easy through a separate access door (with gasket) on each duct. The spray heads feature tri-clamp fittings for easy removal. Particulate matter is removed from the unit by simply draining the water from the unit.
System Specifications:
-
Point of Manufacture: Hutchinson, KS
-
Parts Stocking Location: Hutchinson, KS and Overland Park, KS
-
Cabinet Design: Fully-welded, 14 ga 304 SS exterior cabinet & duct
-
Cleaning Action: Four-Duct design provides four (4) individual washing chambers. Spray nozzles apply water in the opposite direction of air flow. The initial series of nozzles (located in the first duct) spray fresh water. The remaining three (3) series spray re-circulated water.
-
Dimensions (approx): 80" long x 24" wide x 108" high
-
Fresh Water: 480/3/60 - 3.0 hp and 120/1/60 (20 amp breaker) for solenoid operation
-
Cleaning Connection: Potable water 45 psi, approximately 4 GPM - ½" NPT connection
-
Recirculation Pump: ½" NPT for cleaning solution, vertical design with 304 SS construction
-
Cabinet Materials: 304 stainless steel
-
Drain Valves: 2" bronze ball valves - manual operation
-
Chamber Inspection: Each chamber has a gasketed, removable door with cast 304 SS wing-nuts that are removed for system inspection and spray header removal
-
Spray Header Materials: 304 SS tubing with tri-clamp connections with 304 SS spray nozzles
-
Level Control: Included to prevent pump operating without water present
-
Gas Inlet: 12" diameter flanged connection
-
Clean Gas Outlet: 14" diameter flange connection
-
Installation: Must be located in an area that does not experience temperatures below freezing
-
Finish: Glass bead welds
-
System Control: On-board level control maintains adequate reservoir volume while smokehouse control starts pump and cleaning action when smoke cycle begins
-
Diverter Valve: One (1) each included, pneumatic actuated, 304 SS materials